NModbus4.Wrapper
1.0.0
There is a newer version of this package available.
See the version list below for details.
See the version list below for details.
dotnet add package NModbus4.Wrapper --version 1.0.0
NuGet\Install-Package NModbus4.Wrapper -Version 1.0.0
This command is intended to be used within the Package Manager Console in Visual Studio, as it uses the NuGet module's version of Install-Package.
<PackageReference Include="NModbus4.Wrapper" Version="1.0.0" />
For projects that support PackageReference, copy this XML node into the project file to reference the package.
paket add NModbus4.Wrapper --version 1.0.0
The NuGet Team does not provide support for this client. Please contact its maintainers for support.
#r "nuget: NModbus4.Wrapper, 1.0.0"
#r directive can be used in F# Interactive and Polyglot Notebooks. Copy this into the interactive tool or source code of the script to reference the package.
// Install NModbus4.Wrapper as a Cake Addin #addin nuget:?package=NModbus4.Wrapper&version=1.0.0 // Install NModbus4.Wrapper as a Cake Tool #tool nuget:?package=NModbus4.Wrapper&version=1.0.0
The NuGet Team does not provide support for this client. Please contact its maintainers for support.
NModbus4.Wrapper
- NModbus4.Wrapper
- 1. Instruction
- 2. API Information
- 2.1. namespace NModbus4.Wrapper.Define
- 2.2. namespace NModbus4.Wrapper
1. Instruction
- This wrapper class use C# NModbus4 dll
- GitHub : NModbus4.Wrapper
- Blog : Peponi
- Instruction & API information is on following section
1.1. About NModbus4
NModbus is a C# implementation of the Modbus protocol.
Provides connectivity to Modbus slave compatible devices and applications.
Supports serial ASCII, serial RTU, TCP, and UDP protocols.
NModbus4 it's a fork of NModbus(https://code.google.com/p/nmodbus).
NModbus4 differs from original NModbus in following:
1. removed USB support(FtdAdapter.dll)
2. removed log4net dependency
3. removed Unme.Common.dll dependency
4. assembly renamed to NModbus4.dll
5. target framework changed to .NET 4
1.1.1. NModbus4 License
The MIT License (MIT)
Copyright (c) 2006 Scott Alexander, 2015 Dmitry Turin
Permission is hereby granted, free of charge, to any person obtaining a copy
of this software and associated documentation files (the "Software"), to deal
in the Software without restriction, including without limitation the rights
to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
copies of the Software, and to permit persons to whom the Software is
furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in
all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN
THE SOFTWARE.
1.2. About NModbus4.Wrapper
NModbus4.Wrapper is driven from NModbus4 for integrated usage.
Difference of NModbus4.Wrapper from NModbus4 is:
1. integrate class (RTU, TCP, UDP...) into ModbusService
2. support C# data types (bool, int, float)
3. support threading when using Client
1.2.1. NModbus4.Wrapper License
The MIT License (MIT)
Copyright (c) 2023 Peponi
Permission is hereby granted, free of charge, to any person obtaining a copy
of this software and associated documentation files (the "Software"), to deal
in the Software without restriction, including without limitation the rights
to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
copies of the Software, and to permit persons to whom the Software is
furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in
all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN
THE SOFTWARE.
1.3. Code Example
1.3.1. From constructor to connect
string interfaceName = "Test";
ModbusType modbusType = ModbusType.TCP_Slave;
int slaveNo = 1;
EthernetInformation ethernetInformation = new EthernetInformation
{
Address = "127.0.0.1",
Port = 50001
};
Endian endian = Endian.Big;
ModbusInterface interfaceData = new ModbusInterface(interfaceName, modbusType, slaveNo, ethernetInformation, endian);
ModbusService modbus = new ModbusService(interfaceData, CheckConnectionStatus);
modbus.ModbusLog += Modbus_LogWrite;
modbus.ModbusDataReceived += Modbus_ModbusDataReceived;
modbus.ModbusCommunicationException += Modbus_ModbusCommunicationException;
modbus.ModbusGeneralException += Modbus_ModbusGeneralException;
modbus.Connect();
void CheckConnectionStatus(ModbusInterface modbusInterface, bool connectStatus)
{
if (connectStatus)
{
// Do something...
}
else
{
// Reconnect, or other things to do..
}
}
1.3.2. Disconnect
modbus.Dispose();
1.3.3. Restart
if (modbus != null) modbus.Dispose();
modbus = new Modbus(interfaceData, CheckConnectionStatus);
modbus.ModbusLog += Modbus_LogWrite;
modbus.ModbusDataReceived += Modbus_ModbusDataReceived;
modbus.ModbusCommunicationException += Modbus_ModbusCommunicationException;
modbus.ModbusGeneralException += Modbus_ModbusGeneralException;
modbus.Connect();
1.3.4. Read data synchronous
// 1. Single case
var commData = new CommunicationData(DataStorage.HoldingRegister, 0, default(double), modbus.Interface.EndianOption);
if (modbus.ReadData(ref commData))
{
// Data process...
}
else
{
// Do something for error handling...
}
// 2. List case
List<CommunicationData> commDatas = new List<CommunicationData>();
commDatas.Add(new CommunicationData(DataStorage.HoldingRegister, 0, default(float), modbus.Interface.EndianOption));
commDatas.Add(new CommunicationData(DataStorage.HoldingRegister, 2, default(bool), modbus.Interface.EndianOption));
commDatas.Add(new CommunicationData(DataStorage.HoldingRegister, 3, default(int), modbus.Interface.EndianOption));
if (modbus.ReadData(ref commDatas))
{
// Data process...
}
else
{
// Do something for error handling...
}
1.3.5. Write data asynchronous
// 1. Single case
var commData = new CommunicationData(DataStorage.HoldingRegister, 0, 10.12, modbus.Interface.EndianOption);
if (!await modbus.WriteDataAsync(commData))
{
// Do something for error handling...
}
// 2. List case
List<CommunicationData> commDatas = new List<CommunicationData>();
commDatas.Add(new CommunicationData(DataStorage.HoldingRegister, 0, 3.465F, modbus.Interface.EndianOption));
commDatas.Add(new CommunicationData(DataStorage.Coil, 0, true, modbus.Interface.EndianOption));
commDatas.Add(new CommunicationData(DataStorage.HoldingRegister, 2, 534, modbus.Interface.EndianOption));
if (!await modbus.WriteDataAsync(commDatas))
{
// Do something for error handling...
}
2. API Information
2.1. namespace NModbus4.Wrapper.Define
2.1.1. enum LogLevel
Name | Value |
---|---|
Communication | 1 |
Exception | 2 |
2.1.2. enum CommunicationException
Name | Value | Description |
---|---|---|
SlaveFunctionCodeException | 1 | |
SlaveUnimplementedException | 2 | |
MasterTransportNullException | 3 | Remote connection lost |
2.1.3. enum DataType
- Support data type
Name | Value |
---|---|
Bool | 1 |
Int | 2 |
Float | 4 |
2.1.4. enum ModbusType
- Set Network type, Master / Slave mode
Name | Value |
---|---|
RTU_Master | 1 |
TCP_Master | 2 |
UDP_Master | 3 |
RTU_Slave | 11 |
TCP_Slave | 12 |
UDP_Slave | 13 |
2.1.5. enum DataStorage
Name | Value |
---|---|
Coil | 0 |
DiscreteInput | 1 |
InputRegister | 2 |
HoldingRegister | 3 |
2.1.6. enum Endian
- Remote's endian matching enum
Name | Value |
---|---|
Big | 1 |
Little | 2 |
2.1.7. struct SerialPortInformation
Type | Name |
---|---|
string | Port |
int | Baudrate |
System.IO.Ports.Parity | Parity |
int | Databits |
System.IO.Ports.StopBits | Stopbits |
System.IO.Ports.Handshake | Handshake |
2.1.8. struct EthernetInformation
Type | Name |
---|---|
string | Address |
int | Port |
2.1.9. class CommunicationData
- Built in type for communication of NModbus4.Wrapper
2.1.9.1. Members, Methods
- Members
Type | Name | Description |
---|---|---|
DataStorage | DataStorage | |
DataType | DataType | |
Endian | RemoteEndian | |
ushort | StartAddress | Address of data. StartAddress >= 0 |
object | Value | bool, int, float |
- Methods
Return type | Method | Description |
---|---|---|
void | CommunicationData(DataStorage, ushort, object, Endian) | ctor |
List<ushort> | GetHexData() | Parsing Value to hex data |
2.1.10. class ModbusInterface
2.1.10.1 Members, Methods
- Members
Type | Name | Description |
---|---|---|
const int | TransactionLimit | For packet dividing |
string | Name | |
ModbusType | ModbusType | |
int | SlaveNumber | For master mode |
SerialPortInformation? | SerialPortInformation | |
EthernetInformation? | EthernetInformation | |
Endian | EndianOption | Remote's endian |
- Methods
Return type | Method | Description |
---|---|---|
void | ModbusInterface(string, ModbusType, int, SerialPortInformation, Endian) | ctor |
void | ModbusInterface(string, ModbusType, int, EthernetInformation, Endian) | ctor |
2.2. namespace NModbus4.Wrapper
2.2.1. class ModbusService
2.2.1.1 Members, Methods, Events
Members
Type Name Description ModbusInterface Interface Communication information Methods
Return type Method Description void ModbusService(ModbusInterface, Action<ModbusInterface, bool>) ctor void Connect() Connect to remote master / slave void Dispose() Disconnect connection / release thread Action<ModbusInterface, bool> ConnectCallback Connection status changed notice Read methods bool ReadData<T>(DataStorage, int, out T) Read function bool ReadData<T>(DataStorage, int, int, out List<T>) Read function bool ReadData(ref CommunicationData) Read function using built in type bool ReadData(ref List<CommunicationData>) Read function using built in type Task<(bool, T)> ReadDataAsync<T>(DataStorage, int) Async read function Task<(bool, List<T>)> ReadDataAsync<T>(DataStorage, int, int) Async read function Task<(bool, CommunicationData)> ReadDataAsync(CommunicationData) Async read function using built in type Task<(bool, List<CommunicationData>)> ReadDataAsync(List<CommunicationData>) Async read function using built in type Write methods bool WriteData<T>(DataStorage, int, T) Write function bool WriteData<T>(DataStorage, int, List<T>) Write function bool WriteData(CommunicationData) Write function using built in type bool WriteData(List<CommunicationData>) Write function using built in type Task<bool> WriteDataAsync<T>(DataStorage, int, T) Async write function Task<bool> WriteDataAsync<T>(DataStorage, int, List<T>) Async write function Task<bool> WriteDataAsync(CommunicationData) Async write function using built in type Task<bool> WriteDataAsync(List<CommunicationData>) Async write function using built in type Master methods - Slave methods void ClearDataStore() Clear and initialize all data Events
Type Event Description void ModbusGeneralExceptionHandler(ModbusInterface) Deal general, unknown exception void ModbusCommunicationExceptionHandler(ModbusInterface, CommunicationException) Usually need to recreate class for communication after called this event void ModbusLogHandler(ModbusInterface, LogLevel, string) Modbus log Master events - Slave events void ModbusDataReceivedHandler(ModbusInterface, DataStorage, List<int>, List<ushort>) Remote master wrote data to this slave
Product | Versions Compatible and additional computed target framework versions. |
---|---|
.NET Framework | net472 is compatible. net48 was computed. net481 was computed. |
Compatible target framework(s)
Included target framework(s) (in package)
Learn more about Target Frameworks and .NET Standard.
-
.NETFramework 4.7.2
- NModbus4 (>= 2.1.0)
NuGet packages
This package is not used by any NuGet packages.
GitHub repositories
This package is not used by any popular GitHub repositories.
Version 1.0.0:
First release