ProteomIQon 0.1.0

dotnet add package ProteomIQon --version 0.1.0
                    
NuGet\Install-Package ProteomIQon -Version 0.1.0
                    
This command is intended to be used within the Package Manager Console in Visual Studio, as it uses the NuGet module's version of Install-Package.
<PackageReference Include="ProteomIQon" Version="0.1.0" />
                    
For projects that support PackageReference, copy this XML node into the project file to reference the package.
<PackageVersion Include="ProteomIQon" Version="0.1.0" />
                    
Directory.Packages.props
<PackageReference Include="ProteomIQon" />
                    
Project file
For projects that support Central Package Management (CPM), copy this XML node into the solution Directory.Packages.props file to version the package.
paket add ProteomIQon --version 0.1.0
                    
#r "nuget: ProteomIQon, 0.1.0"
                    
#r directive can be used in F# Interactive and Polyglot Notebooks. Copy this into the interactive tool or source code of the script to reference the package.
#:package ProteomIQon@0.1.0
                    
#:package directive can be used in C# file-based apps starting in .NET 10 preview 4. Copy this into a .cs file before any lines of code to reference the package.
#addin nuget:?package=ProteomIQon&version=0.1.0
                    
Install as a Cake Addin
#tool nuget:?package=ProteomIQon&version=0.1.0
                    
Install as a Cake Tool

ProteomIQon - computational proteomics

Product Compatible and additional computed target framework versions.
.NET net5.0 was computed.  net5.0-windows was computed.  net6.0 was computed.  net6.0-android was computed.  net6.0-ios was computed.  net6.0-maccatalyst was computed.  net6.0-macos was computed.  net6.0-tvos was computed.  net6.0-windows was computed.  net7.0 was computed.  net7.0-android was computed.  net7.0-ios was computed.  net7.0-maccatalyst was computed.  net7.0-macos was computed.  net7.0-tvos was computed.  net7.0-windows was computed.  net8.0 was computed.  net8.0-android was computed.  net8.0-browser was computed.  net8.0-ios was computed.  net8.0-maccatalyst was computed.  net8.0-macos was computed.  net8.0-tvos was computed.  net8.0-windows was computed.  net9.0 was computed.  net9.0-android was computed.  net9.0-browser was computed.  net9.0-ios was computed.  net9.0-maccatalyst was computed.  net9.0-macos was computed.  net9.0-tvos was computed.  net9.0-windows was computed.  net10.0 is compatible.  net10.0-android was computed.  net10.0-browser was computed.  net10.0-ios was computed.  net10.0-maccatalyst was computed.  net10.0-macos was computed.  net10.0-tvos was computed.  net10.0-windows was computed. 
.NET Core netcoreapp2.0 was computed.  netcoreapp2.1 was computed.  netcoreapp2.2 was computed.  netcoreapp3.0 was computed.  netcoreapp3.1 was computed. 
.NET Standard netstandard2.0 is compatible.  netstandard2.1 was computed. 
.NET Framework net461 was computed.  net462 was computed.  net463 was computed.  net47 was computed.  net471 was computed.  net472 was computed.  net48 was computed.  net481 was computed. 
MonoAndroid monoandroid was computed. 
MonoMac monomac was computed. 
MonoTouch monotouch was computed. 
Tizen tizen40 was computed.  tizen60 was computed. 
Xamarin.iOS xamarinios was computed. 
Xamarin.Mac xamarinmac was computed. 
Xamarin.TVOS xamarintvos was computed. 
Xamarin.WatchOS xamarinwatchos was computed. 
Compatible target framework(s)
Included target framework(s) (in package)
Learn more about Target Frameworks and .NET Standard.

NuGet packages (1)

Showing the top 1 NuGet packages that depend on ProteomIQon:

Package Downloads
QualIQon

QualIQon - Visual quality control for computational proteomics

GitHub repositories

This package is not used by any popular GitHub repositories.

Version Downloads Last Updated
0.1.0 71 11/16/2026
0.0.11 152 9/2/2026
0.0.10 616 6/2/2025
0.0.9 719 3/23/2025
0.0.8 2,468 2/13/2023
0.0.7 706 9/13/2021
0.0.6 701 8/20/2021
0.0.5 709 6/18/2021
0.0.4 671 5/14/2021
0.0.1 737 4/21/2021

Add StoreIsotopePatterns to the PSMStatistics parameters and the default parameters
Add IsotopePatterns: the isotope pattern of a peptide at a charge (MIDA, resolution 0.01, minimum probability 0.001) for the quantification tools, its BLOB encoding, the table IsotopePattern of the peptide data base with a look up that reads the table and computes missing patterns, and the function that stores the patterns
Add SpectrumIndex (the MS1 index and the MS2 headers from one pass over the spectrum descriptions, skipping with a warning the descriptions that cannot be read) and SortedSearch (binary searches and the closest scan time), and the m/z sort of the peaks of a spectrum in SortedPeaks, shared by the quantification and search tools
Use CrossValidation and no PEP cutoff (PepValueThreshold 1.0) in the default PSMStatistics parameters
Add Charts.useReferenceEqualityForJson, which makes saving Plotly.NET charts faster with the same output
Add the local scan time error scale, the source run, the source model error and the predicted ion mobility with its error scale to AlignmentResult, the .align row of QuantBasedAlignment
Breaking: change the parameters of AlignmentBasedQuantification (AlignmentBasedQuantificationParams) and its default parameters: PerformLocalWarp is removed, PerformLabeledQuantification is a Labeling as in QuantificationParams, and MinScanTimeWindow, ScanTimeWindowSdFactor, DecoyFraction, Seed, RequirePeakAtScanTime and IonMobilityWindow in XicExtraction are added
Breaking: replace the parameters of AlignmentBasedQuantStatistics (AlignmentBasedQuantStatisticsParams), PositiveQuantMzCutoff, NegativeQuantMzCutoff, PositiveQuantCutoff and NegativeQuantCutoff, by the label, feature, trainer, absent-analyte FDR and seed parameters, and change its default parameters
Remove PSMStatisticsResultFragpipe. MsFraggerToPSM writes and PSMBasedQuantificationTIMs reads PSMStatisticsResult
Write warnings to the log file of the tools
Add CrossValidation to the PSMStatistics EstimationParams
Add BaselineAls, the ALS baseline of FSharp.Stats baselineAls' computed faster with the same values, shared by PSMBasedQuantification, PSMBasedQuantificationTIMs and AlignmentBasedQuantification
Update BioFSharp.Mz to 0.2.3
Speed up the wavelet peak detection of FSharpStats'.Wavelet with the same results
Update MzIO to 0.1.8, MzIO.Processing to 0.1.8, MzIO.SQL to 0.1.10 and MzIO.MzML to 0.1.11
FSharpStats'.Wavelet.identify uses the parameters it is given, which were ignored before, and handles short traces, on which it failed
Set MinPeakDistance 0.1 in the default parameters QuantificationParams
Use the Wavelet peak detection with the ALS baseline correction in the default parameters QuantificationTIMsParams
Add RetentionTimeFeature to the PSMStatistics EstimationParams, true in the default parameters
Correct the default parameters QuantificationParams_NoBaseline, which could not be read, and make them equal to QuantificationParams except for the baseline correction
Set Alignment_QValue 0.05 in the default parameters of LabelFreeProteinQuantification and LabeledProteinQuantification
Set MinPepLength 6 in the default parameters of PeptideDB
Add Xic, MzCalibration, PeakQuantification and PSMQuantification: the XIC of an ion (on spectra with ion mobility the sum of all peaks inside the m/z window and the ion mobility window, for a fixed window around the ion mobility centre of the ion), the m/z correction of a run, the peak detection and the choice of the peak, and the quantification of the PSMs of an ion with its quality filter, shared by PSMBasedQuantification, PSMBasedQuantificationTIMs and AlignmentBasedQuantification
Breaking: change QuantificationParams, the parameters of PSMBasedQuantification and PSMBasedQuantificationTIMs, and the default parameters: remove FragPipe and add QualityFilterLog2Limit, CentrePSMs, RequirePeakAtScanTime and IonMobilityWindow in XicExtraction
Remove DTW', the dynamic time warping of the alignment tools
Add PeakShape, the apex and the standard deviation of a fitted peak from its Gaussian or exponentially modified Gaussian parameters, used by the alignment tools
Add the column IonMobilityCentre as the last column of the .quant row (QuantificationResult): the ion mobility the XIC of the row is summed around, NaN without an ion mobility window. Breaking: QuantBasedAlignment, AlignmentBasedQuantification and AlignmentBasedQuantStatistics do not read .quant files without it
Set MzWindow_Da Fixed 0.008 and IonMobilityWindow Fixed 0.025 in the default parameters QuantificationTIMsParams and add AlignmentBasedQuantificationTIMsParams, the default parameters of AlignmentBasedQuantification with the same two values