Movensys.BlackBox.Core 1.1.1

dotnet add package Movensys.BlackBox.Core --version 1.1.1
                    
NuGet\Install-Package Movensys.BlackBox.Core -Version 1.1.1
                    
This command is intended to be used within the Package Manager Console in Visual Studio, as it uses the NuGet module's version of Install-Package.
<PackageReference Include="Movensys.BlackBox.Core" Version="1.1.1" />
                    
For projects that support PackageReference, copy this XML node into the project file to reference the package.
<PackageVersion Include="Movensys.BlackBox.Core" Version="1.1.1" />
                    
Directory.Packages.props
<PackageReference Include="Movensys.BlackBox.Core" />
                    
Project file
For projects that support Central Package Management (CPM), copy this XML node into the solution Directory.Packages.props file to version the package.
paket add Movensys.BlackBox.Core --version 1.1.1
                    
#r "nuget: Movensys.BlackBox.Core, 1.1.1"
                    
#r directive can be used in F# Interactive and Polyglot Notebooks. Copy this into the interactive tool or source code of the script to reference the package.
#:package Movensys.BlackBox.Core@1.1.1
                    
#:package directive can be used in C# file-based apps starting in .NET 10 preview 4. Copy this into a .cs file before any lines of code to reference the package.
#addin nuget:?package=Movensys.BlackBox.Core&version=1.1.1
                    
Install as a Cake Addin
#tool nuget:?package=Movensys.BlackBox.Core&version=1.1.1
                    
Install as a Cake Tool

Movensys.BlackBox.Core

A library for collecting motion, digital I/O, and analog I/O status data from WMX3-based systems. It records data in real-time using WMX3's memory logging feature and saves the data with pre/post trigger conditions. CSV and JSON files are automatically generated for analysis with MotionScope.

Requirements

  • .NET Framework 4.5 or later
  • WMX3 Runtime must be installed

Features

  • Real-time data logging with WMX3 Memory Log
  • Configurable monitored axes and I/O channels
  • Pre-trigger / Post-trigger data collection support
  • Auto-generation of CSV + JSON files compatible with MotionScope
  • Launch MotionScope directly with the generated data

Basic Usage Example

using Movensys.BlackBox.Core;
using Movensys.BlackBox.Core.Models;

// Initialization
var blackBox = BlackBoxManager.GetBlackBoxService();
blackBox.CreateDevice();
blackBox.InitMemoryLog();

// Configure axes
blackBox.SetBlackBoxAxes(new List<BlackBoxAxisInfo>
{
    new BlackBoxAxisInfo { AxisIndex = 0, AxisDataType = AxisDataType.CommandPos, Name = "Axis0" },
    new BlackBoxAxisInfo { AxisIndex = 1, AxisDataType = AxisDataType.FeedbackVelocity, Name = "Axis1" },
});

// Configure Digital I/O
blackBox.SetBlackBoxDigitalIO(new List<DigitalIOAddress>
{
    new DigitalIOAddress { Byte = 0, Bit = 0, Name = "Start", Type = IoType.Input },
    new DigitalIOAddress { Byte = 1, Bit = 0, Name = "AlarmReset", Type = IoType.Output }
});

// Start logging
blackBox.SetLoggingCycle(preCycleCount: 10000, postCycleCount: 500);
blackBox.StartBlackBox();

// Trigger occurs
blackBox.SaveBlackBoxData();

// Stop logging after completion
blackBox.StopBlackBox();

// Open MotionScope with saved data
blackBox.StartMotionScope(@"C:\BlackBoxLogs\20250717\BlackBoxData_Alarm.csv");

Unit Mode - Equipment with Many Units (1.1.0)

For equipment made of many identical units (dozens of units, each with a few axes and sensors) where alarms occur per unit, often several at once. Equipment with only a handful of axes keeps using the basic mode above (axes and I/O configured directly).

How It Works

 One engine memory-log channel (axes + digital inputs of every unit)
        | every cycle (GetMemoryLogData, up to 100 cycles per read)
        v
 Ring buffer in code (Pre + Post + 2,048 cycles, preallocated)   <- collection keeps running during a dump
        | SaveBlackBoxData(name, units) = trigger
        v
 Window [trigger - Pre, trigger + Post], selected units' columns only -> writer thread -> CSV + JSON (MotionScope)
  • Only one channel is used. Memory-log channels are an engine-wide resource (16 in total) shared by every program, so one channel per unit would run out quickly.
  • The axes and inputs of all units are collected together, and only the faulted unit + neighboring units are copied into a dump.
  • The first trigger defines the window. Other triggers that arrive before the window is complete (simultaneous alarms on other units) add their names and units to the same dump and are listed in _Triggers.txt. Repeated alarms do not keep pushing the window back.
  • A trigger that arrives after the window is complete starts a new dump. Collection never stops, so its pre-trigger data is intact (1.0.x stopped and restarted the memory log for each dump, so an alarm right after a dump had no pre-trigger data).

Usage Example

using Movensys.BlackBox.Core;
using Movensys.BlackBox.Core.Enums;
using Movensys.BlackBox.Core.Models;

var bb = BlackBoxManager.GetBlackBoxService();   // created on the first call (throws here if the WMX runtime is missing - catch it on the caller side)
if (!bb.CreateDevice()) return;
if (bb.InitMemoryLog() != 0) { bb.Close(); return; }   // no idle channel = BlackBoxService.ErrorNoIdleChannel (-1)
bb.SetLogFilePath(@"D:\App\Log_BlackBox");
bb.SetLoggingCycle(preCycleCount: 3000, postCycleCount: 1000);   // 1 ms cycle = 3 s before / 1 s after

var units = new List<BlackBoxUnit>();
foreach (var unit in machineUnits)
{
    var u = new BlackBoxUnit { Name = unit.Name };
    u.Axes.Add(new BlackBoxAxisInfo { AxisIndex = unit.Axis, AxisDataType = AxisDataType.CommandVelocity, Name = $"{unit.Name} Axis" });
    u.Axes.Add(new BlackBoxAxisInfo { AxisIndex = unit.Axis, AxisDataType = AxisDataType.FeedbackVelocity, Name = $"{unit.Name} Axis" });
    u.Axes.Add(new BlackBoxAxisInfo { AxisIndex = unit.Axis, AxisDataType = AxisDataType.FeedbackPos, Name = $"{unit.Name} Axis" });
    u.DigitalIO.Add(new DigitalIOAddress { Name = $"{unit.Name} Sensor", Type = IoType.Input, Byte = unit.SensorByte, Bit = unit.SensorBit });
    units.Add(u);
}
bb.SetBlackBoxUnits(units);        // the same axis / data type / address is collected only once
bb.DumpSaved += (csv, names, gaps) => Log($"BlackBox {csv} [{string.Join(",", names)}] gaps {gaps}");
bb.StartBlackBox();

// On an alarm (the unit + its neighbors)
bb.SaveBlackBoxData("UNIT_03_SENSOR_TIMEOUT", new[] { "UNIT_03", "UNIT_02", "UNIT_04" });

// Always on program exit (returns the channel and closes the device).
// A forced kill does not return the channel (it is freed when the engine restarts).
bb.Close();

Output Files

Under {log path}\yyyy\MM\dd\HH\yyyyMMdd_HH_mm_ss_fff_BlackBoxData_{first trigger name}

File Contents
.csv MotionScope format (AxisDataType,MotionScope / Config,1 / Cycle,{data type}-{axis},...,Input-{byte}.{bit}). Selected units' columns only
.json MotionScope chart settings. Unit mode = one chart per axis data type (e.g. command velocity / feedback velocity / position) + an input chart. Neighboring units overlap on the same chart, so speed synchronization and sensor order can be compared. Marker line = trigger row
_Triggers.txt Only when the window has two or more triggers or the engine log has gaps: row position and name of each trigger, number of missing cycles

To open in MotionScope: bb.StartMotionScope(csvPath), or open the CSV in WMX WOS\MotionScope.exe (the JSON with the same name is used as the chart settings).

Status / Errors (1.1.0)

Property / Event Meaning
LastError / LastErrorText Last error (memory-log read, channel, file write). InitMemoryLog: no idle channel → ErrorNoIdleChannel; an idle channel could not be opened → that WMX code (1.1.1)
ReadErrorCount Number of memory-log read failures (1.0.x dropped them silently)
GapCycles Accumulated engine memory-log gaps (skipped CycleCounter). The engine buffer holds 1,024 cycles, so a gap occurs when the collection thread cannot read for longer than that (about 1 s at a 1 ms cycle)
SkippedTriggers Number of triggers dropped because collection was not running
DumpSaved Raised after a dump file is written (CSV path, trigger names, gaps in that window)

Limits (WMX Memory Log)

  • Up to 128 axes, 128 bytes of digital input (1,024 bits) and 128 bytes of digital output.
  • Unit-mode inputs are digital only (analog = basic mode).
  • Memory = ring rows x (axis columns x 8 B + 128 B each for input and output). Example: (3,000 pre + 1,000 post + 2,048) rows x 210 axis columns = about 10 MB, + I/O 1.5 MB.

Log Storage Path

By default, log files are stored in the application's working directory. You can change the location with SetLogFilePath(). Log files are saved in a date/time-based folder structure and include both CSV data and JSON metadata.

Important Notes

  • Requires a valid WMX3 license and driver installation.
  • Make sure to call Close() after CreateDevice() to release resources properly.

Release History

Nov 17, 2026 - 1.1.1 ver<br> Axis columns read from the memory-log output slot of the axis selection order (axisData[cycle][n], n = n-th selected axis). 1.1.0 and earlier read slot = axis number, which only matched when the selected axes start at 0 and are contiguous (e.g. axes 0 ~ 4); other selections (e.g. axes 90 · 91, or a selection starting at axis 32) were saved as 0. Axis selection is now sorted ascending. CreateDevice checks whether the device is alive (1.1.0 checked the device name, so a second start after Close ran without a device); Close also closes a channel buffer that was opened but never started; InitMemoryLog returns the status-read error when channel status cannot be read (e.g. CommNotStarted 0x601 = called before WMX communication starts - start the black box after communication is running), and when it finds no usable channel, LastErrorText lists every channel status (ch0:Running ch1:Idle open 0x... ...). Digital IO CSV columns are named Input-{byte}.{bit} / Output-{byte}.{bit} - the MotionScope format; the earlier Input-{bit number} columns made MotionScope show 'Load(JSON CSV File)' listing every input series (checked by opening a dump in WOS\MotionScope.exe). InitMemoryLog returns the first OpenMemoryLogBuffer error when idle channels exist but none could be opened (1.1.0 overwrote it with ErrorNoIdleChannel). Verified with random digital-input patterns (40 patterns over 3 bytes, non-contiguous bits: order · values · hold length ± 1 ms) and jogging axes 90 / 91 (command velocity · feedback position).

Nov 17, 2026 - 1.1.0 ver<br> Multi-unit equipment (many identical units · alarms in bursts): continuous collection (memory log is no longer stopped while a dump is written - a second alarm right after keeps its pre-trigger data), preallocated ring of the configured axis columns / IO bytes (no per-cycle 128-axis objects), first trigger defines the window and later triggers inside it are listed in _Triggers.txt, SaveBlackBoxData(name), DumpSaved event, read errors / cycle gaps exposed (LastError · ReadErrorCount · GapCycles), unique file names (ms), InitMemoryLog returns ErrorNoIdleChannel when no idle channel, Close stops collection and closes the channel buffer, BlackBoxManager creates the service lazily (no WMX CLR object in the static constructor).

Jul 16, 2026 - 1.0.78 ver<br> Fixed a crash when the configured log path is unavailable, added a fallback to the default directory, prevented re-triggering from postponing an in-progress dump, and removed an unused Peek() that threw on an empty buffer.

Product Compatible and additional computed target framework versions.
.NET net5.0 is compatible.  net5.0-windows was computed.  net6.0 was computed.  net6.0-android was computed.  net6.0-ios was computed.  net6.0-maccatalyst was computed.  net6.0-macos was computed.  net6.0-tvos was computed.  net6.0-windows was computed.  net7.0 was computed.  net7.0-android was computed.  net7.0-ios was computed.  net7.0-maccatalyst was computed.  net7.0-macos was computed.  net7.0-tvos was computed.  net7.0-windows was computed.  net8.0 is compatible.  net8.0-android was computed.  net8.0-browser was computed.  net8.0-ios was computed.  net8.0-maccatalyst was computed.  net8.0-macos was computed.  net8.0-tvos was computed.  net8.0-windows was computed.  net9.0 was computed.  net9.0-android was computed.  net9.0-browser was computed.  net9.0-ios was computed.  net9.0-maccatalyst was computed.  net9.0-macos was computed.  net9.0-tvos was computed.  net9.0-windows was computed.  net10.0 was computed.  net10.0-android was computed.  net10.0-browser was computed.  net10.0-ios was computed.  net10.0-maccatalyst was computed.  net10.0-macos was computed.  net10.0-tvos was computed.  net10.0-windows was computed. 
.NET Framework net45 is compatible.  net451 is compatible.  net452 is compatible.  net46 is compatible.  net461 is compatible.  net462 is compatible.  net463 was computed.  net47 is compatible.  net471 is compatible.  net472 is compatible.  net48 is compatible.  net481 is compatible. 
Compatible target framework(s)
Included target framework(s) (in package)
Learn more about Target Frameworks and .NET Standard.

NuGet packages (1)

Showing the top 1 NuGet packages that depend on Movensys.BlackBox.Core:

Package Downloads
Movensys.BlackBox.WinForms

Created by Movensys Application Team with BlackBox functionality

GitHub repositories

This package is not used by any popular GitHub repositories.

Version Downloads Last Updated
1.1.1 0 11/23/2026
1.0.46 269 7/17/2025